Two tabletop xenon test chambers allowing aging tests at xenon light exposure. Economical and perfec
WhatsApp: +86 13816217984
E-postadress:info@qinsun-lab.com
Radiant energy in the STD SOLARBOX is provided by a single superior air-cooled Xenon Lamp generating an irradiance level up to two times the sun one. Irradiance is the rate at which light energy falls onto the samples. A weathering tester must control irradiance if it is to achieve accurate and reproducible test results. STD SOLARBOX offers constant measurement and control of rradiance during every test, compensating for lamp and UV filter ageing via a closed loop irradiance narrow-band sensor control system.
Irradiation uniformity is guaranteed by a parabolic reflector chamber with the Xenon Lamp in the focus, the best design for a reliable flat-bed xenon exposure system and very good agreement with rotating drum xenon exposures.
ADHESIVES: ASTM D904; ASTM C1442; ASTM
C1501; RILEM DBS.
AUTOMOTIVE: SAE J2527; SAE J2412.
COATINGS: QUALICOAT; ISO 2135; ISO 11341;ASTM D3451; ASTM D3794; ASTM D6577; ASTMD6695; GB 1865; JIS K 5600-7-7; MPI: #113; MS133: Part F14.
DENTISTRY: ISO 4049:2000; ISO 7491:2000.
GENERAL: IEC 68-2-9; ISO 4892-1; ASTM G151;ASTM G155.
GEOTEXTILES: ASTM D4355.
INTRA-OCULAR LENSES: ISO 11979-5:2006
INKS/PAPER: ISO 11798; ISO 12040; ISO 18909;ASTM D3424; ASTM D4303; ASTM D5010; ASTM D6901; ASTM F2366.
PACKAGING: ASTM D6551.
PHARMACEUTICAL: ICH Guideline Q1B.
PLASTICS: ISO 4892-2; JIS K 7350-2; DIN EN 513;ASTM D1248; ASTM D2565; ASTM D4101; ASTM D4459; ASTM D5071; ASTM D6662; UL 1581.
ROOFING: ASTM D4434; ASTM D4637; ASTM D4798; ASTM D4811; ASTM D5019; ASTM D6083.
RUBBER: ISO 3865; ISO 4665.
SEALANTS: ASTM C1442; ASTM C1501.
TEXTILES: AATCC TM 16; AATCC TM 169; GB/T8430; IS: 2454; ISO 105-B02.
SOLARBOX Model | 1500 | 1500e | 3000 | 3000e |
Electrical connection | ||||
Mains voltage | 230 Vac 10%, 50/60 Hz. | |||
Mains connection | 1/N/PE | |||
Current consumption | 16 A (max.) | |||
Measures and weight | 1500 | 1500e | 3000 | 3000e |
Mått | 750 x 390 x 400 mm. | 890 x 390 x 400 mm. | ||
Exposure area (Horizontal Specimen Holder) | 280 x 200 mm. | 420 x 200 mm. | ||
weight | 30 Kg | 32 Kg | ||
Number of specimen panels (15 x 30 mm.) | more than 120 | more than 180 |
Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.