Fire resistance test furnace for building materials

Technical parameters:Gas used: methane flow rate (35 ± 0.5)L/min, its purity is greater than 95%, ai

E-postadress: info@standard-groups.com

Innehåll

Technical parameters:

Gas used: methane flow rate (35 ± 0.5)L/min, its purity is greater than 95%, air flow rate (17±0.2)L/min

Specimen size: Each test takes 4 specimens as a group

Thermocouple: nickel-chromium-nickel-silicon thermocouple with a wire diameter of 0.5mm and an outer diameter not greater than 3mm

Furnace wall temperature: Room temperature ——100°C ——1 °C

Intake temperature: 0——50±0.5°C

Pressure difference: 0——30Pa±1Pa

Pressure difference measurement range: 0-100pa, accuracy :0.2%

Temperature recorder and thermostat: multi-channel continuous temperature recording and curve display

Constant temperature: (23±2)°C

Constant current: (10+1)m3/min

Ambient temperature: 19——30°C

Power supply: 380VAC 50HZ

Dimensions of combustion shaft furnace: 1020mmx1020mmx3930mm

Internal size of combustion shaft furnace: 800mmx800mmx2000mm


企业微信截图_17417481693584.png

企业微信截图_17417481765183.png

企业微信截图_17417481827104.png

企业微信截图_17417481905038.png

企业微信截图_17417481998802.png


Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.


Nätmeddelande

Kontaktuppgifter

Företagstelefon

+86-21-6420 0566

Arbetstider

måndag till fredag

Mobiltelefon:

13816217984

E-post:

info@qinsun-lab.com

QR-kod