The Vertical Flammability Chamber, designed for American Standards, measures the vertical flame spread for children's sleepwear, fabrics, other textile materials or resilient filling materials used in upholstered furniture.

Standarder

ASTM D6413. CALIF TB117. DOC-FF 3/71. 16CFR Parts1615/1616. FTMS 191-5903. CPAI 84

Ansökan

The vertical burning of textiles is suitable for all types of fabrics and their products. Test method applicable to the burning performance of the bottom edge of the vertical textile specified in GB5455-2014 standard.

Egenskaper

Gas pipeline system special designed, low space occupied, and convenience to move;

Exhaust vents at the bottom and top of test chamber ensure good ventilation and steady flame;

LED displayer shows the igniting time, afterflame time and afterglow time, with high working efficient and the data more accuracy;

A stainless steel construction, large glass-viewing window;

Excellent reliability and minimum maintenance;

Purpose-designed test chamber.

Parameter

 


ItemParameter
Inner sizeAbout 330*330*765mm.
Windowstempered glass observation window
Exhaust holes16pcs proof holes,6pcs each side(total 12pcs)
Exhaust diameter12.5mm
Proof hanging clamplocated 17mm above the highest point of the igniter nozzle.
Diameter of the igniter nozzle11mm
Angle about the head and vertical line25°
inlet gas pressure of the igniter17.2kpa±1.7kpa
Ignition timeaccurate to 0.05s
Gas sourceindustrial grade propane, butane or propane / butane mixed gas. When the sample is pretreated according to 7.3 in GB5455-2014. methane gas with a purity of not less than 97% is selected.
Sample size300*89mm, five horizontal and vertical
Ambient temperature-10 ° C ~ 30 ° C
Power supply voltage220V±10% 50HZ
Kraftless than 100W
Flame time0-99M99S
Flame time accuracy± 0.01s
Afterglow timelongest 0-99M99S
Blue flame height15mm-175mm with flame height scale
Ignition timeany setting (can be preset)


 
 

Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.