Tests geosynthetic resistance to clogging by soil particles.
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
Tillämpningsområde:
The method of gradient ratio is used to measure the permeability coefficient and permeability ratio of soil and geotextile system and its interface under no-pressure conditions, and the mud content of geotextile is measured to determine whether the geosynthetic material is used as a filter layer of some soil, and whether the blockage is not allowed.
Uppfyller standarden:
ASTM D5101-2006JTG E50 T1145-2006,SL/T 235-33-2012, etc
Instrumentfunktioner:
Suitable for all kinds of soil and geotextile;
Floor type design, stable fuselage structure, not easy to deformation:
Plexiglass test chamber can visually observe the silting process of geotextiles:
The seal of the specimen holding device in the test cylinder is good to ensure the feasibility of the test.
The height of the test cylinder is reasonable, and a certain space is reserved above the soil sample to make the water flow uniform and stable.
Manual rotary hand wheel drive, water level regulation, efficient and smooth:
6 pressure gauges for easy pressure observation and high measurement accuracy:
Easy to install, easy to operate.
Tekniska parametrar:
Instrument type floor type
The inner diameter of the test cylinder is 100mm
The sample height is 100mm
Head difference adjustment range 0——1050mm
Head difference accuracy ±1mm
Support net aperture 6mm
Overall dimensions 450x400x980mm(LxWxH)
Weight 75kg
Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.