Sulfur Dioxide and Hydrogen Sulfide Corrosion Test Chamber for Automotive Connectors

Meeting Standards:Carry out various sulfur dioxide gas corrosion tests in accordance with GB10587 -

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Innehåll

Meeting Standards:

Carry out various sulfur dioxide gas corrosion tests in accordance with GB10587 - 89, GB2423.9 - 93, GJB150, QC/T417.1 - 2001 and equivalent standards such as IEC, DIN, MIL, ASTM.


Tekniska parametrar:

1. Temperature range: 10 - 55°C 2. Temperature fluctuation: ±0.5°C 3. Temperature uniformity: ±2°C 4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm) 5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm) 6. Relative humidity: 75±3% 7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.


Environmental Requirements:

1. Power supply: AC380V 3Φ 10KVA 0HZ 2. Allowable voltage range: ±5% of the rated value 3. Maximum load: 6KVA 4. The distance between the chamber and the wall should be greater than 600cm.


Structural Materials and Features:

1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean. 2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens. 3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber. 4. Humidification method: Humidification by a steam generator. 5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors. 6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).


Control System:

1. Temperature control: Japanese Fuji temperature controller 2. Temperature input: PT100; Output: Driven by SSR 3. Display range: 0 - 100°C 4. Control range: RT + 5 - 55°C 5. Cycle used (measurement filtering): 2 - 3s 6. The main control components are products from joint - venture companies. 7. The temperature is controlled by a solid - state relay, with stable performance and no noise. 8. A fan is used for stirring and circulation inside the chamber. 9. Display and control of sulfur dioxide concentration



Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.