Industrial water purifier - Qinsun
Tillverkare av professionella provningsinstrument
Nationell hotline för samråd:+86 021-64208466

Industrial water purifier

Industrial pure water machines are essential systems designed to produce high-purity water by removi

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Innehåll

Tillämpliga standarder

Industrial water purifier systems adhere to global purity and safety benchmarks, including:

  • ASTM D1193 (Specifications for Reagent Water)
  • USP <643> (Total Organic Carbon in Pharmaceutical Waters)
  • ISO 3696 (Water for Analytical Laboratory Use)
  • SEMI F57 (Ultrapure Water Specifications for Semiconductor Manufacturing)
  • GB/T 6682 (China’s National Standard for Laboratory Water)

These standards define purity levels (e.g., resistivity ≥18.2 MΩ·cm, TOC <10 ppb) for specific industries.

Huvudparametrar


ParameterSpecifikation
Purity LevelsType I (Ultrapure: 18.2 MΩ·cm), Type II (Deionized: 1–15 MΩ·cm)
Flow Rate1–100 L/min (customizable for production scale)
TechnologiesReverse Osmosis (RO), Electrodeionization (EDI), Ultraviolet (UV) Sterilization, 0.22μm Filtration
Feed Water RequirementsTap water (TDS <1,000 ppm), pre-treated water for advanced systems
Energy Consumption0.5–5 kW/h (variable by capacity and technology)
Control SystemPLC automation with conductivity/TOC monitors, alarms, and data logging

Arbetsprincip

The system employs a multi-stage purification process:

  1. Pre-treatment: Sediment/carbon filters remove large particles, chlorine, and organic matter.
  2. Reverse Osmosis (RO): Semi-permeable membranes reject 95–99% of dissolved salts and ions.
  3. Electrodeionization (EDI): Ion-exchange resins and electric fields further polish water to ultrapure levels.
  4. UV Sterilization: 185/254 nm wavelengths destroy bacteria and degrade TOC.
  5. Ultrafiltration: 0.22μm filters ensure particle-free output.

Test Principle & Validation

Pure water systems undergo rigorous testing:

  • Resistivity/Conductivity: Real-time monitoring to verify ion removal (18.2 MΩ·cm = 0.055 μS/cm).
  • Total Organic Carbon (TOC): Oxidation-based analyzers detect organic contaminants (<10 ppb for semiconductor use).
  • Microbial Testing: Membrane filtration or ATP bioluminescence assays confirm sterility (<1 CFU/mL).
  • Endotoxin Validation: LAL (Limulus Amebocyte Lysate) tests ensure <0.03 EU/mL for pharmaceutical applications.

Ansökningar include:

  • Pharmaceuticals: Sterile water for injection (WFI) and cleaning validation.
  • Elektronik: Rinsing wafers in semiconductor fabrication.
  • Power Plants: Boiler feedwater to prevent scaling.
  • Laboratories: HPLC solvents and analytical reagent preparation.

Industrial pure water machines are indispensable for industries demanding zero-tolerance contamination, offering scalable, efficient, and validated solutions for critical processes.

Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.