Ultraviolet Fluorescence UV Sulfur Content Tester ASTM D5453 - Qinsun
Tillverkare av professionella provningsinstrument
Nationell hotline för samråd:+86 021-64208466
Produkter

Ultraviolet Fluorescence UV Sulfur Content Tester ASTM D5453

Detailed Product DescriptionSample Type:Liquid, Solid And GasDetermination Method:UV Fluorescen

WhatsApp: +86 13816217984

E-postadress:info@qinsun-lab.com

Innehåll

Detailed Product Description

Sample Type:Liquid, Solid And GasDetermination Method:UV Fluorescence Method
Sample Injection Amount Solid Sample:1-20mgLiquid Sample:5-20μL
Gas Sample:1-5mLMeasuring Range:0.1-5000mg/L
Temperature Control Range:Room Temperature To 1300 °CTemperature Control Accuracy:± 1 °C
Working Power:AC220V±10% 50HzPower:1500 W
Dimensions Host:305(W)×460(D)×440(H)mmWeight Host:20kg
Highlight:

ASTM D5453 UV Sulfur Analyzer

UV Fluorescence Sulfur Content Tester

Ultraviolet Fluorescence Sulfur Content Tester

Produktbeskrivning:

Ultraviolet Fluorescence Sulfur Meter is a new generation analytical instrument developed based on the combination of ultraviolet fluorescence fluorescence principle and computer technology. Suitable for the determination of naphtha, distillates, motor fuels and other petroleum products. Applied to the determination of naphtha, distillate oil, motor fuel and other petroleum products.

Applicable standards: SH/T 0689. ASTM D5453. GB/T11060.8

Technical Features:

The system uses ultraviolet fluorescence method to measure the total sulfur content.

It improves the ability of anti-impurity interference, avoids the cumbersome operation of the titration cell by the coulometric method and the resulting unstable factors, and greatly improves the sensitivity of the instrument.

The key parts of the system use devices to stabilize the performance of the whole machine.

The software is intuitive and easy to learn, and the standard curve and results are automatically saved without data loss.

Tekniska parametrar:

Sample Type Liquid, Solid and Gas

Determination Method UV Fluorescence Method

Sample Injection Amount Solid Sample: 1-20mg Liquid Sample: 5-20μL Gas Sample: 1-5mL

Measuring Range 0.1-5000mg/L

Measurement Accuracy Fluorescence Sulfur Meter Injection Amount (μL) RSD (%)

Concentration values (ppm)Injection quantity(µL)RSD(%)
51010
50105
100103
5000103

Temperature control range :Room temperature to 1300 °C

Temperature control accuracy: ± 1 °C

Gas source requirements High-purity argon: high-purity oxygen with a purity of 99.995% or more : Purity above 99.99%

Working power :AC220V±10% 50Hz

Power: 1500 W

Dimensions Host: 305(W)×460(D)×440(H)mm

weight host: 20kg

Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.