Detailed Product DescriptionSTD:Open Cup Flash Point TesterThermometer:(-6 ~ 400)°CFlame Diamet
WhatsApp: +86 13816217984
E-postadress:info@qinsun-lab.com
STD: | Open Cup Flash Point Tester | Thermometer: | (-6 ~ 400)°C |
---|---|---|---|
Flame Diameter: | 3.2mm ~ 4.8mm | Ambient Temperature: | (-10∼50)°C |
Maximum Power Consumption: | 650W | Dimension: | 350mm×290mm×350mm |
Keywords: | Cleveland Open Cup Closed-Cup Flash Point Tester | ||
Highlight: | oil analysis equipmentoil testing equipment |
Cleveland Open Cup Flash Point Tester is designed and made as per standards GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland Open Cup Method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils.
1. It adopts special heating furnace to ensure the safety of test. The heating power is continuously adjustable. It can meet requirements of test.
2. The instrument adopts desktop structure. The stainless steel working table and furnace shell make it beautiful and elegant.
3. The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas.
4. It equipped with flame extinguishing cover which accord with requirements of test.
1. Power supply: AC (220±10%) V, 50Hz.
2. Heating device: Quartz tube furnace heating, no naked fire, explosion prevented. The power is adjustable from 0W to 600W.
3. Test flame applicator: It applies the test flame automatically.
4. Thermometer: (-6 ~ 400)°C. It is the same as thermometer ASTM 11C.
5. Igniting device: (1) Ignition source: coal gas(or civil gas)
(2) Flame diameter is 3.2mm ~ 4.8mm
6. Ambient temperature: (-10∼50)°C
7. Relative humidity: ≤85%
8. Maximum power consumption: 650W
9. Dimension: 350mm×290mm×350mm (thermometer is not included)
Item | Unit | Qty | Remarks |
Oil cup | Piece | 1 | |
Ignition | Set | 1 | |
Thermometers (-6~400 ℃, scale division is 2 ℃) | Piece | 1 | |
Thermometer support | Set | 1 | |
5A fuse(∅5×20) | Piece | 2 | |
Latex pipe∅6 | Meter | 1.5 | Connecting the inlet port of the instrument |
Gas pipe connecting head | Piece | 1 | Gas pipe and latex tube adapter |
Flameout cover | Piece | 1 |
Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.