Specific Surface Area and Pore Size Analyzer - Qinsun
Tillverkare av professionella provningsinstrument
Nationell hotline för samråd:+86 021-64208466
Produkter

Analysator för specifik yta och porstorlek

SelectionInstrument ModelInstrument NameMain FunctionsSTD-660SSpecific Surface Area and Po

WhatsApp: +86 13816217984

E-postadress:info@qinsun-lab.com

Innehåll

standards

GB/T 3163-2007

GB/T 19587-2017

HG/T 2382

Selection

Instrument ModelInstrumentnamnHuvudfunktioner
STD-660SAnalysator för specifik yta och porstorlekAdsorption analysis at liquid nitrogen temperature 77K, such as BET specific surface area analysis, meso-pore volume and pore size analysis.
STD-660MAvancerad analysator för specifik yta och mikroporerIncluding functions of 660S, supports micropore analysis at 87K/Ar, 195K/CO2. etc., with micropore volume and pore size analysis capabilities.
STD-660MGAvancerad gasadsorption och mikroporeanalysatorIncluding functions of 660M, fully automatic continuous adsorption analysis for various gases and multiple temperature points, and fully automatic cycle adsorption lifetime evaluation.
STD-660MCAvancerad korrosiv gasadsorption och mikropore analysatorIncluding functions of 660MG, with adsorption analysis capabilities for corrosive gases such as NH3. SO2. BF3.
STD-660MVÅnga-/gassorption och mikroporenalysator (volymmetod)Including functions of 660MG, with adsorption analysis capabilities for water vapor and organic vapors.



Hårdvara skillnaderTest TemperaturesRoutine Configurations (Number of Analysis Positions)Commonly Tested Materials
Oil pump, single-stage pressure sensor, solenoid valve, P/P0 lower limit better than E-5Standard: 3L Dewar flask, liquid nitrogen 77K, liquid argon 87KA3S, A6S, A3S, B3S, A6S, B6SNon-porous materials such as lithium battery materials, inorganic salts, oxides, hydroxides, metal powders, organic materials
Compared to 660S, configured with molecular pump, multi-stage pressure sensor, gas-controlled diaphragm valve and other micropore configurations, P/P0 lower limit better than E-9Standard: 3L Dewar flask, constant temperature circulating bath, -10℃~80℃A3M, A6M, A6S.B3M, A6S.B6M, A3M.B3M, A6M.B6M.Porous materials such as zeolite molecular sieves, activated carbon, MOF, COF, HOF, porous carbon, silica gel
Compared to 660M, configured with automatic multi-channel intake module and constant temperature bath communication function, multi-channel gas automatic switching, automatic flushing, automatic adsorption temperature switching.Same as aboveA3MG, A6MG, A6S|B3MG, A3MG|B3MG, A6MG|B6MG-
Compared to 660MG, pipelines, valves, pressure sensors, sealing materials, etc., have stronger corrosion resistance, and equipped with corrosive adsorbate enrichment device.Same as aboveA3MC, A6MC, A3MG-
Compared to 660MG, a vapor adsorption module is added, equipped with a vapor enrichment device to reduce vapor contamination of pump oil.Same as aboveA3MV, A6MV, A3MG|B3MV, A3MC|B3MV

Huvudfunktion

◆ Full-functional: Specific surface area, mesopore, and micropore analysis;

◆ High-throughput: Optional analysis stations (3/6/9/12);

◆ Fully automatic: Degassing → Testing, fully automatic switching;

◆ Anti-contamination: "Pressure-controlled heating" for micropore sample degassing to prevent contamination;

◆ Zero helium contamination: Pre-heating zone with helium gas, followed by automatic degassing;

◆ Auto-cycling: Automatic evaluation of material cyclic adsorption performance.

Technical Parameter◆ Broad testing range: Specific surface area ≥0.0005 m²/g, pore size 0.35-500 nm;

◆ Testing efficiency: Multi-point BET (excluding degassing process), standard mode 12 samples/60 min; rapid testing mode 12 samples/15 min;

◆ High testing accuracy: Quantitative error of specific surface area, pore size, pore volume, and adsorption capacity <0.5% RSD (based on standard sample BET value);

◆ Temperature-programmed degassing: Software-controlled temperature programming, room temperature to 400°C, accuracy better than 0.1°C;

◆ Intelligent degassing completion judgment: Software-supported automatic judgment based on pressure changes to evaluate degassing effectiveness;

◆ Anti-dust degassing: Pressure-controlled heating + pressure-controlled vacuuming to completely eliminate sample dusting during degassing;

◆ Vacuum level: 10⁻² Pa;

◆ High reliability: International supplier system, core components imported with original packaging.

Tekniska fördelar

◆ High-throughput and high-efficiency

Stöder analys av upp till 12 prover samtidigt.

◆ Truly fully automated

International first: automatic switching between degassing furnace and Dewar cup, no manual transfer of sample tubes or degassing furnace required;

◆ High time utilization

Solves the time waste issue of conventional instruments where degassing is completed after work hours, but testing cannot start. Enables sample loading after work and data viewing the next day;

◆ Complete elimination of "helium contamination"

Pioneering solution in the international arena: helium gas dead volume test → vacuum heating degassing → adsorption test, improving test accuracy by addressing the helium contamination challenge in micropore analysis;

◆ Anti-dust degassing

Supports "pressure-controlled heating" + "pressure-controlled vacuuming", automatically adjusting temperature programming and vacuuming rate based on pressure changes to prevent sample dusting;

◆ Supports automatic cycle testing

Automatic degassing + testing cycle for evaluating material adsorption performance stability and adsorption lifespan;

Teknisk parameter

◆ Wide Test Range: Specific surface area above 0.0005 m²/g, pore size 0.35-500 nm.

◆ Testing Efficiency: Multi-point BET (excluding degassing process), standard mode 12 samples/60 min; rapid test mode 12 samples/15 min.

◆ High Testing Accuracy: Quantitative error of specific surface area, pore size, pore volume, and adsorption capacity is less than 0.5% RSD (based on the BET value of standard samples).

◆ Temperature-programmed Degassing: Software-controlled temperature programming, room temperature to 400℃, accuracy better than 0.1℃.

◆ Intelligent Degassing Completion Judgment: Supports automatic software judgment, automatically judges the degassing effect based on pressure changes.

◆ Anti-飞扬 Degassing: Pressure-controlled heating + pressure-controlled vacuum pumping, a two-pronged approach to completely solve the phenomenon of sample 飞扬 during the degassing process.

◆ Vacuum Degree: 10-2 Pa.

◆ High Reliability: International supplier system, core components are all imported.

Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.


Nätmeddelande

Kontaktuppgifter

Företagstelefon

+86-21-6420 0566

Arbetstider

måndag till fredag

Mobiltelefon:

13816217984

E-post:

info@qinsun-lab.com

QR-kod