Thermal protective clothing tester evaluates RPP and TPP performance.
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
Inledning
Thermal protective clothing and some fire-retardant properties of the material refers that human body carry out security protection who work under high temperature conditions, so as to avoid the human body's high temperature injury. In theory, there are three forms of heat damage to the human body:
thermal convection; B. heat transfer; C. thermal radiation;
In general, the practical application is more than the above two or three kinds of mixing effect. So the thermal protection should be used for different purposes and use of the environment to highlight its certain thermal protection performance.
I. Thermal Radiation Protection Performance Test Method (RPP Test) Radiant Protective Performance;
II. Thermal Radiation and Heat Convection Mixing Protective Performance Test Method (TPP Test) Thermal Protective Performance;
The RPP test is mainly used to determine the radiant thermal protection performance of thermal protective clothing. Since thermal radiation is one of the main heat transfer forms that cause thermal damage. The method can better test and evaluate the thermal protection performance of thermal protective clothing from one aspect, and has been widely used in the field of forest fire.
Egenskaper
◆ Evaluation of flame retardant properties of flame retardant materials
◆ Detect abnormalities and reduce accidents
◆ Calculate the RPP value
◆ Evaluate thermal protection performance
◆ Improve job safety
◆ Improve the quality control system
Tekniska parametrar
Objekt | Parametrar |
Heating power | 6.5Kw/220V/50Hz |
Heating length | 178mm, diameter 8mm |
Heat flux density | 10Kw/m2-80Kw/m2 |
Radiation source temperature control | -1200℃±5℃ |
Thermal radiation source temperature sensor | Thermocouple (0 ℃ -1600 ℃) |
Calorimeter heat capacity | 480.937J/K |
Heating area | 50mm2×50mm2 |
Calorimeter temperature range | -80℃ |
Test environment | Between 15 ℃ -35 ℃ ,the room without air circulation |
Ansvarsfriskrivning: Ovanstående innehåll är endast för referens och kommunikation mellan branschinsider, och garanterar inte dess riktighet eller fullständighet. Enligt gällande lagar och förordningar och förordningar på denna webbplats ska enheter eller individer som köper relaterade artiklar erhålla giltiga kvalifikationer och kvalifikationsvillkor.
Företagstelefon
+86-21-6420 0566
Arbetstider
måndag till fredag
Mobiltelefon:
13816217984
E-post:
info@qinsun-lab.com